{"product_id":"major-tech-250v-10kv-diagnostic-hv-insulation-mt577","title":"Major Tech 10kV Diagnostic Insulation Tester | MT577","description":"\u003cp\u003e\u003cstrong\u003eMajor Tech 10kV Diagnostic Insulation Tester | MT577\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- --\u003e Details \u003cp\u003eThe MT577 10kV Diagnostic Insulation Tester with increments of 50V on each range will automatically discharge the circuit after the test has been completed. Using the range button switches, 6 preset ranges of 250V, 500V, 1000V, 2500V, 5kV and 10kV can be selected, with an insulation resistance up to 35TΩ. The microprocessor controlled MT577 has the capability of being a diagnostic tool and is intended for testing insulation on Rotating Machines, Transformers, Cables, High Voltage Generators, Electric Circuits and Surge Arresters. The short circuit current output is up to 6mA. It has the function of measuring Absorption Ratio and Polarization Index of AC voltage and DC voltage and 500 test measurement results can be saved in the memory of the meter and recalled onto the LCD display. The large backlit LCD display indicates the readings of insulation, measuring time, output voltage and output current. The MT577 can measure up to 750V AC and up to 1000V DC and Capacitance up to 50μF, and is housed in a robust case ideal for extended field use, powered by 12.6V Lithium batteries. Stored data \u003cbr\u003ecan be transferred to a PC using an optical USB and software supplied.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003c!-- --\u003e Specifications: \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 250V\u003c\/td\u003e \u003ctd\u003e0.1MΩ~1000GΩ\u003c\/td\u003e \u003ctd\u003e0.001MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 500V\u003c\/td\u003e \u003ctd\u003e0.2 MΩ~2000GΩ\u003c\/td\u003e \u003ctd\u003e0.001MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 1000V\u003c\/td\u003e \u003ctd\u003e0.5MΩ~5000GΩ\u003c\/td\u003e \u003ctd\u003e0.001MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 2500V\u003c\/td\u003e \u003ctd\u003e1MΩ~10TΩ\u003c\/td\u003e \u003ctd\u003e0.01MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 5000V\u003c\/td\u003e \u003ctd\u003e2MΩ~10TΩ\u003c\/td\u003e \u003ctd\u003e0.01MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation 10KV\u003c\/td\u003e \u003ctd\u003e5MΩ~35TΩ\u003c\/td\u003e \u003ctd\u003e0.01MΩ\u003c\/td\u003e \u003ctd\u003e±3%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC voltage\u003c\/td\u003e \u003ctd\u003e0.1V~1000V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd\u003e±1.5%rdg±3dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAC voltage\u003c\/td\u003e \u003ctd\u003e0.1V~750V\u003c\/td\u003e \u003ctd\u003e0.1V\u003c\/td\u003e \u003ctd\u003e±1.5%rdg±3dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDC current\u003c\/td\u003e \u003ctd\u003e0.01nA – 6mA\u003c\/td\u003e \u003ctd\u003e1pA\u003c\/td\u003e \u003ctd\u003e±30%rdg ± 5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCapacitance\u003c\/td\u003e \u003ctd\u003e10nF – 50µF\u003c\/td\u003e \u003ctd\u003e0.1nf\u003c\/td\u003e \u003ctd\u003e±10%fs.±5dgt\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBasic condition\u003c\/td\u003e \u003ctd\u003e23°C ± 5°C, below 75%RH\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated voltage\u003c\/td\u003e \u003ctd\u003e250V, 500V, 1000V, 2500V, 5kV, 10kV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTest Voltage(V)\u003c\/td\u003e \u003ctd\u003eRated voltage x (1±10%)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOutput short-circuit Current\u003c\/td\u003e \u003ctd\u003e≥6mA@15KV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAbsorption, Ratio and Polarization Index Measurement\u003c\/td\u003e \u003ctd\u003e Yes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePower Supply\u003c\/td\u003e \u003ctd\u003e12.6V rechargeable battery\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eBacklight\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDisplay Mode\u003c\/td\u003e \u003ctd\u003e4-bit large LCD display, grey screen backlight\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLCD display size\u003c\/td\u003e \u003ctd\u003e108mm x 65mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstrument size\u003c\/td\u003e \u003ctd\u003e240mm x 188mm x 85mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eUSB interface\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eCommunication Line\u003c\/td\u003e \u003ctd\u003eUSB communication line 1PC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eTest Lead\u003c\/td\u003e \u003ctd\u003eHigh voltage probe red 3m, high voltage test lead black 1.5m, green 1.5m\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Storage\u003c\/td\u003e \u003ctd\u003e500 groups\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eData Review\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOverflow Display\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAlarm Function\u003c\/td\u003e \u003ctd\u003eAlarm when the measured value larger or smaller than the alarm setting value\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInstrument weight\u003c\/td\u003e \u003ctd\u003e2750g (including battery)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLow Battery Display\u003c\/td\u003e \u003ctd\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAutomatic shut-down\u003c\/td\u003e \u003ctd\u003eAutomatic shutdown after 15 minutes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eInsulation Resistance\u003c\/td\u003e \u003ctd\u003e≥50MΩ (between Measuring line and housing)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePressure Resistance\u003c\/td\u003e \u003ctd\u003eAC3kV \/ 50Hz 1min\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWorking Temperature and Humidity\u003c\/td\u003e \u003ctd\u003e-10°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eStorage Temperature and Humidity\u003c\/td\u003e \u003ctd\u003e-15°C to 55°C \u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSafety Regulations\u003c\/td\u003e \u003ctd\u003eIEC61010-1, IEC1010-2-31, IEC61557-1,5, \u003cp\u003eIEC60529 (IP54) pollution grade 2, CAT III 300V\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSupplier SKU:\u003c\/strong\u003e MT577\u003c\/p\u003e","brand":"Major Tech","offers":[{"title":"Default Title","offer_id":48510511284441,"sku":"MT577","price":29279.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/9464\/4185\/files\/MT577_20Web.jpg?v=1782291969","url":"https:\/\/www.chavda.com\/products\/major-tech-250v-10kv-diagnostic-hv-insulation-mt577","provider":"chavda.com","version":"1.0","type":"link"}