{"product_id":"major-tech-earth-resistivity-resistance-tester-cat-iii-300v-k4106","title":"Major Tech Earth Resistivity and Resistance Tester | K4106","description":"\u003cp\u003e\u003cstrong\u003eMajor Tech Earth Resistivity and Resistance Tester | K4106\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- --\u003e Details \u003cp\u003eThe K4106 is a 2\/3\/4-wire Digital Earth resistance\/Earth Resistivity Tester equipped with a microcomputer and can measure earth resistances and calculate earth resistivity’s (ρ), using the “Wenner” 4 pole method. This instrument is ideal for Earth measurements also in large Earthing systems because it uses a considerable test current of 80mA(max) yielding a high resolution of 1mΩ on 2Ω range. The Earth Resistivity measurement is useful for soil surveys to establish the optimum earth electrode system design and site, to avoid extra cost of reworking electrode installations. It can also be suitable for geological investigations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003c!-- --\u003e Specifications: \u003ctable\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eMeasuring range\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eEarth resistance Re\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e(Rg at ρ measurement\u003c\/strong\u003e)\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e2Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.001Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.03 to 2.099Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e±(2%rdg±0.03Ω)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e20Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.01Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.03 to 20.99Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e± (2%rdg±5dgt (*1)) \u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e200Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.1Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.3 to 209.9Ω\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e2000Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e1Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e3 to 2099Ω\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e20kΩ\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e10Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.03 to 20.99kΩ\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e200kΩ\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e100Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.3 to 209.9kΩ\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eAuxiliary earth resistance Rh, Rs\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e \u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e \u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e \u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e(8% of Re+Rh+Rs)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eEarth resistivity ρ\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e2Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.1 to 1Ω·m\u003cbr\u003eAuto-ranging\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.2 to 395.6Ω·m\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e(ρ=2×π×a×Rg (*2)) \u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e20Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.2 to 3956Ω·m\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e200Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e20 to 39.56kΩ·m\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e2000Ω\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.2 to 395.6kΩ·m\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e20kΩ\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e2.0 to 1999kΩ·m\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e200kΩ\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eSeries interference voltage Ust (A.C only) (*3) \u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e50V\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.1V\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0 to 50.9Vrms\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e± (2%rdg ± 2dgt (50\/60Hz))\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e± (3% rdg ± 2dgt (40 to 500Hz))\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eFrequency Fst\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eAuto-ranging\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e0.1Hz\u003cbr\u003e1Hz\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e40Hz to 499.9Hz\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e± (1% rdg ± 2 dgt)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eMeasuring\u003c\/strong\u003e \u003cstrong\u003emethod\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eEarth resistance: Fall-of-potential method\u003cbr\u003e(currents and voltages measured via the Probes)\u003cbr\u003eMeasurement method of Earth Resistivity (ρ): Wenner 4-pole method\u003cbr\u003eSeries interference voltage (earth voltage)\u003cbr\u003eRMS Rectifier (between the E-S Terminals)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eMemory capacity\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e800 data\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003ePC Intgerface\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eLCD Display\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eOver-range Indication\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eYes\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eOverload Protection\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003ebetween E-S(P) and between E-H(C) terminals AC280V \/ 10 sec.\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003ePower source\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eR6 × 8\u003cbr\u003e(Auto power off: Approx. 5 minutes)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eDimension\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003e167(L) × 185(W) × 89(D) mm\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eApprox. 900g (including batteries)\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e \u003cp\u003e\u003cstrong\u003eSafety Specs\u003c\/strong\u003e\u003c\/p\u003e \u003c\/td\u003e \u003ctd\u003e \u003cp\u003eIEC 61010 – CAT II 600V and CAT III 300V\u003c\/p\u003e \u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSupplier SKU:\u003c\/strong\u003e K4106\u003c\/p\u003e","brand":"Major Tech","offers":[{"title":"Default Title","offer_id":48510465048793,"sku":"K4106","price":39269.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/9464\/4185\/files\/K4106-accessories-4_f2f28f97-249b-49a5-adb8-89eb9bf9b3dd.jpg?v=1782291441","url":"https:\/\/www.chavda.com\/products\/major-tech-earth-resistivity-resistance-tester-cat-iii-300v-k4106","provider":"chavda.com","version":"1.0","type":"link"}